All
Compatible Software Version
iREWORK LCD Screen Shown information details
- Serial number and Firmware version.
- 50Hz/60Hz current frequency
- 3.xxV actual voltage for control
- H is the heating temperature
- Bt is box temperature
- Hp heater power rate, If not work show OFF
- Op the selected profile & option number
- T is K type tip temperature reader
- E is extra Thermocouple temperature readings (use for seperate Screen by wide plate, this need connect ESP)
- WAIT the process not started, ended or idle state, If process are running will show ‘WORKING’
- No other action next procedure and time information
Short press button ‘S’ one time can choose/change operation option by press ‘▲’ ‘▼’
- SETUP - 6 current operation option
- H 260<265 current heater ‘target’ < ‘maximum’ temperature
- Remove A10 CPU current operation description
Long press button ‘S’ one time can adjust target temperature by press ‘▲’ ‘▼’
- Adjust H current operation heater option
- Target 260 current heater target temperature, this temperature can not be more than maximum
Ps. Once adjusted temperature or changed options need press one time ‘S’ to confirm settings, if don't save setting press one time ‘F’ to quite
Holding and press button ‘▲’ to check the current operation option heating temperature and Extra temperature settings(Only Options 1 with Extra temperature)
Holding and press button ‘▼’ to check the current settings, like Fans settings, next procedure info etc
Do you think this tutorial is helpful?